    In ftServer 2600, 4500, and 6300 systems running simplexed and at high temperature, all fans operate at maximum speed and continue to operate, unless the thermal threshold is reached, which causes an abrupt power shutdown. The front panel ID LED blinks blue when either one or both of the system Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) The blinking LEDs help you locate a specific enclosure that may be mounted in a heavily populated rack. In Windows, you can cause the system ID LEDs to blink by issuing the Start Slot Identification command from ftSMC. PCI adapter LEDs indicate the operational status of the PCI adapters. See the Stratus ftServer Systems: PCI Adapter Guide (R461) for details. Hard Disk Drive Status LEDs. If you are unable to fix the condition, contact the CAC or your authorized Stratus service representative. Troubleshooting the Hardware 3-11. Figure 3-4 shows the LEDs for the Ethernet ports and VTM ports. 3-12 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Troubleshooting the Hardware 3-13. The modem assembly has a green power LED and a yellow attention (fault or identify) LED. 3-14 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Table 3-7 describes the modem-assembly LED states. See your system administration documentation for information about component failures and ways to correct them. C A U T I O N Do not remove the modem assembly when it is powered on (steady green LED). Modem is being identified. See your system administration documentation for the procedure to identify a modem. Modem is unsafe to remove. 3-16 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) N O T E In the table, MPS refers to main power source, and TVS refers to transient voltage suppression. If you cannot resolve the problem, contact the yellow CAC or your authorized Stratus service representative.

    • ftserver 2600 manual, ftserver 2600 manual pdf, ftserver 2600 manual download, ftserver 2600 manual free, ftserver 2600 manual downloads.

    Replacing the System Backpl. DIMM Slot Numbering in Sing. DIMM Slot Numbering in Dual. DIMM Ejector Levers Removing the Power Supply F. Removing the PCI Adapter Br. Removing the PCI Adapter fr. Removing the PCI Bulkhead B. Loosening the Captive Screw. Removing the Bracket from t. Removing an Adapter from th. Inserting a Full-Height Ada. Replacing a Disk Drive Replacing a DVD Drive Replacing the Modem Assembl. Removing the Metal Plate Ov. Replacing a PDU Replacing the Modem Assembly 5-49 Figure 5-28. Removing the Metal Plate Over the Modem Connector 5-50 Figure 5-29. Replacing a PDU 5-52 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) It explains how to start up and shut down the system, how to interpret system operational status based on the state of the light-emitting diodes (LEDs), and how to remove and replace the customer-replaceable units (CRUs). For example: Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Four light pipes on the upper right side of the bezel provide a view of the system status LEDs when the bezel is installed. See Chapter 3 for a description of the LEDs and buttons on the front of the enclosure.The numbers are silk-screened on the enclosure exterior and are the same numbers that identify the slots in the software. See the Stratus ftServer Systems: PCI Adapter Guide (R461) for detailed information about PCI adapters. Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) The increase in fan speed ensures adequate cooling under these conditions and is normal behavior. Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) They will verify your assessment of the failure. For the most current list of CAC or your authorized Stratus service representative locations and telephone numbers, refer to See the Stratus ftServer Systems: PCI Adapter Guide (R461) for information about the LEDs on PCI adapters.

    5-14 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Replacing the Plenum dco015 Plenum Replacing the Plenum 1. Place the plenum as shown in Figure 5-10 and lower it into position until it snaps into place. To seat the plenum properly, slide its sides over the outside of the DIMM slots, and fit its three tabs into the fan assembly. Pull the enclosure out about 4 in. Replacing The System Backplane Assembly The thumbscrews (number 3) on the assembly should line up with the screw holes on the rear of the enclosure. Dimm Slot Numbering In Single-Processor Systems (Viewed From Front) Dimm Slot Numbering In Dual-Processor Systems (Viewed From Front) Tools: Phillips head number 2 screwdriver. 5-26 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Shut down the system. Remove the bezel. Dimm Ejector Levers To replace a faulty DIMM If you must replace DIMMs in different enclosures, work on one enclosure at a time to keep the system operating. N O T E Pull the connector, not the wires, to disconnect the wires. 5-30 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Removing The Power Supply Fan Removing the Power Supply Fan dco020 Power supply fan Screw Fan connector Replacing the Power Supply Fan Assembly 1. Lower the fan into place, being sure to guide its base over the tabs (number 1 in Figure 5-17). If installing adapters in a PCI riser assembly, see “Replacing a PCI Riser Assembly and Its Adapters” on page 5-38. Estimated time: Ten minutes. 5-34 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Use ESD precautions when performing this procedure. N O T E S 1. The PCI slots are physically labeled PCI 1 through PCI 4 on the enclosure chassis. Labeling in Windows software is the same as labeling in the hardware.

    System does not Ensure that the disk drive was installed correctly. See “Removing and recognize disk drive Inserting an Internal Hard Disk Drive”. Table 3-10 lists some problems that the DVD drive could encounter, as well as some corrective actions. 3-20 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) For more sources of technical information about ftServer system hardware or software, “Getting Help”. Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) If you are uncertain about the proper storage conditions for a specific CRU, see “Getting Help”. Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Dispose of used batteries according to the instructions provided with the battery. C A U T I O N When replacing a CRU, always observe the following guidelines. If you are replacing a defective bezel, set it aside for repacking. See “Repacking CRUs” on page 4-3. Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Align the LED light pipes inside the bezel (shown through a cut-away view at number 1 in Figure 5-1) with the right side of the system. Remove the bezel. 2. Loosen the captive thumbscrew (number 2 in Figure 5-2) at the bottom of the front panel (number 1). Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Push down the front end of the lever to disengage it. 5-10 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Keep the enclosure level. 5-12 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) The enclosure returns to service if the other enclosure is operating. If you shut down the system, return it to operation.

    Replacing The Modem Assembly Removing The Metal Plate Over The Modem Connector PDUs are typically located in the bottom 2U of the cabinet.Replacing A Pdu See “Repacking CRUs” on page 4-3. Figure 5-29. Replacing a PDU pdu003 Circuit breaker switch Power-jumper cords Power-input cord Blank side of PDU 5-52 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) See ASN modem assembly, 5-48 antistatic bags, 4-2 PCI riser assembly, 5-38 ASN, 1-1. We have 2 Stratus ftServer 2600 manuals available for free PDF download: Operation And Maintenance Manual, Site Planning Manual. These manuals, which are available in HTML and PDF format, are intended for use by system installers before the arrival of their purchased ftServer system. In addition to these site planning guides, StrataDOC provides access to the complete Stratus manual set. Links to pages in StrataDOC will open in a new browser window. Privacy Policy Service Terms Cookie Preferences. The server automatically manages its replicated components, executing all processing in lockstep. Because replicated components perform the same instructions at the same time, there is zero interruption in processing, zero loss of performance, and zero loss of data integrity even if a component fails. This means that, unlike a high-availability cluster, the Stratus approach does not impose recovery time. Notice The information contained in this document is subject to change without notice.Notice The information contained in this document is subject to change without notice.Stratus documentation describes all supported features of the user interfaces and the application programming interfaces (API) developed by Stratus. Any undocumented features of these interfaces are intended solely for use by Stratus personnel and are subject to change without warning. This document is protected by copyright. 3 All rights are reserved.

    Removing The Pci Adapter Bracket If the adapter does not disconnect easily, use a firm side-to-side tugging motion while maintaining steady pressure on the adapter. 5-36 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Removing The Pci Adapter From The Pci Slot Removing the PCI Adapter from the PCI Slot doc035 PCI adapter PCI adapter connector If you are replacing a defective PCI adapter, set it aside for repacking. See “Repacking CRUs” on page 4-3. Removing The Pci Bulkhead Bracket Screws Loosening The Captive Screw On The Motherboard Removing The Bracket From The Pci Riser Assembly Removing the Bracket from the PCI Riser Assembly dco038 Bracket Screw N O T E Keep track of the removed screw and bracket and keep them in a safe place while performing this procedure. 2. Removing An Adapter From The Connector On The Pci Riser Inserting A Full-Height Adapter Into The Pci Riser Inserting a Full-Height Adapter into the PCI Riser dco039b If you are installing a 6.6 in. (167.75 mm) adapter, place it in the lower slot. If installing a 7.7 in. (195.94 mm) adapter, place it in the upper slot. 2. C A U T I O N Do not pull the drive; use the latch. 5-44 Stratus ftServer 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Replacing A Disk Drive Replacing a Disk Drive dco052 Release button Latch If you are replacing a damaged disk drive, set it aside for repacking. See “Repacking CRUs” on page 4-3. Replacing an Internal Hard Disk Drive With the disk drive lever in the open position, slide the replacement disk drive into the system until it stops. You perform this procedure when replacing a defective DVD drive and also when replacing the system front panel. Replacing A Dvd Drive Replacing a DVD Drive dco033 Thumbscrew 4. Pull the drive from the front panel assembly. If you are replacing a defective drive, set it aside for repacking. See “Repacking CRUs” on page 4-3.

    This information now appears in Stratus ftserver System Software: Installation for Linux Systems (R013L). Preface xi 12 Preface Notation Conventions This document uses the notation conventions described in this section. Warnings, Cautions, and Notes Warnings, cautions, and notes provide special information and have the following meanings. WARNING A warning indicates a situation where failure to take or avoid a specified action could cause bodily harm or loss of life.! CAUTION A caution indicates a situation where failure to take or avoid a specified action could damage a hardware device, program, system, or data. NOTE A note provides important information about the operation of an ftserver system. Typographical Conventions The following typographical conventions are used in this document: The italic font introduces or defines new terms. For example: ftserver systems use replicated, fault-tolerant hardware to eliminate single points of failure and protect data integrity The bold font emphasizes words in text. For example: Update the BIOS before you install or upgrade ftsss.The monospace bold font represents text you must type in examples that contain both user input and system output. The monospace italic font represents terms in command lines that are to be replaced by literal values. Although a prompt is sometimes shown at the beginning of a command line as it would appear on the screen, you do not type it. Users of this account are referred to as root. Preface xiii 14 Preface Ellipses (.) indicate that you can specify the preceding argument as many times as you need to on a single command line. Any list or set of arguments can contain more than two elements. Brackets and braces are sometimes nested. Getting Help If you have a technical question about ftserver system hardware or software, try these online resources first: Online documentation at the StrataDOC Web site.

    Stratus provides complimentary access to StrataDOC, an online-documentation service that enables you to view, search, download, and print customer documentation. You can access StrataDOC at the following Web site: A copy of the StrataDOC CD-ROM for your system is included with this release. To order additional copies of the StrataDOC CD-ROM or to obtain copies of printed manuals, do one of the following: If you are in North America, call the Stratus Customer Assistance Center (CAC) at (800) or (800), 24 hours a day, 7 days a week. If you are located outside North America, contact your nearest Stratus sales office, CAC office, or distributor; for CAC phone numbers outside the U.S., see Online support from Stratus Customer Service. You can find the latest technical information about an ftserver system through online product support at the Stratus Technical Support Web site: Online product support for Red Hat Linux products. Your primary source for support is the manufacturer who provided your software, or Red Hat Global Support Services. You can also find the latest technical information about Red Hat Enterprise and Standard Linux through online product support at the Red Hat Support Web site: xiv Stratus ftserver System Administrator s Guide for the Linux Operating System (R003L) 15 Preface If you are unable to resolve your questions with the help available at these online sites, and the ftserver system is covered by a service agreement, please contact the Stratus Customer Assistance Center (CAC) or your authorized Stratus service representative. For information about how to contact the CAC, see the Web site. Commenting on the Documentation To provide corrections and suggestions on the documentation, send your comments in one of the following ways: By clicking the site feedback link at the bottom of a Help topic. Information to identify the topic is supplied in the StrataDOC Web Site Feedback form.

    No part of this document may be copied, reproduced, or translated, either mechanically or electronically, without the prior written consent of Stratus Technologies. Stratus, the Stratus logo, ftServer, and the ftServer logo are registered trademarks of Stratus Technologies Bermuda, Ltd. The Stratus Technologies logo, the Stratus 24 x 7 logo, ActiveService, ftScalable, and Active Upgrade are trademarks of Stratus Technologies Bermuda, Ltd. The registered trademark Linux is used pursuant to a sublicense from the Linux Mark Institute, the exclusive licensee of Linus Torvalds, owner of the mark on a world-wide basis. 4 FLEXlm is a registered trademark of Macrovision Corporation.All other trademarks are the property of their respective owners. Manual Name: Stratus ftServer 2600, 4500, and 6300 systems: site planning guide Part Number: R638. Revision Number: 02. Software Release Number: ftServer system Software for the Windows Operating system, Release ftServer system Software for the Linux Operating system: Release ftServer system Software for vmware vSphere: Release Publication Date: February 2010. 5 Stratus Technologies, Inc. 111 Powdermill Road Maynard, Massachusetts 01754-3409. 2010 Stratus Technologies Bermuda, Ltd. All rights reserved. Connecting Power to Systems, PDUs, and a UPS 2-10. Connecting a system Directly to a UPS 2-12. Power Cord Summary 2-13. Power Cords for ftServer Systems and Peripheral Components 2-13. PDU Power Cords 2-14.Specific features vary by thin client operating system: What action needs. Software described in Stratus documents (a) is the property of Stratus Technologies Bermuda, Ltd.Stratus documentation describes all supported features of the user interfaces and the application programming interfaces (API) developed by Stratus. Any undocumented features of these interfaces are intended solely for use by Stratus personnel and are subject to change without warning. This document is protected by copyright. All rights are reserved.

    No part of this document may be copied, reproduced, or translated, either mechanically or electronically, without the prior written consent of Stratus Technologies. Stratus, the Stratus logo, ftserver, Continuum, Continuous Processing, StrataLINK, and StrataNET are registered trademarks of Stratus Technologies Bermuda, Ltd. The registered trademark Linux is used pursuant to a sublicense from the Linux Mark Institute, the exclusive licensee of Linus Torvalds, owner of the mark on a worldwide basis. Red Hat, Red Hat Linux, and Red Hat Enterprise Linux are registered trademarks of Red Hat, Inc.All other trademarks are the property of their respective owners. Manual Name: Stratus ftserver System Administrator s Guide for the Linux Operating System Part Number: R003L Revision Number: 09 Software Release Number: ftserver System Software for the Linux Operating System, Release Publication Date: December 2009 Stratus Technologies, Inc. 111 Powdermill Road Maynard, Massachusetts Stratus Technologies Bermuda, Ltd. Revision Information This document is a revision. It incorporates support for ftserver 2600, 4500, and 6300 systems. Numerous changes exist throughout the manual. Notable changes include the following: ftserver 2600, 4500, and 6300 systems support 16 internal disks. This revision provides information on resynchronization in the sections Deferring CPU Resynchronization on page 2-25 and Disabling System Operation During CPU Resynchronization on page The section Using the ftsmaint Command on page 4-1 describes new and changed arguments of the ftsmaint command. Device paths have changed; see Table 2-4 as well as Figure 2-2 and Figure 2-3. Starting with ftserver 2600, 4500, and 6300 systems, VTM functionality is integrated into the baseboard management controller (BMC). Thus, information about the VTM throughout the manual has changed. Previous revisions of this manual included a chapter on the VTM.

    By to If it is possible, please include specific information about the documentation on which you are commenting: For a printed document or a document in PDF format, include the title and part number from the Notice page and the page numbers. For online documentation, include the Help subject and topic title. This information will assist Stratus Information Development in making any needed changes to the ftserver system documentation. Your assistance is most appreciated. Preface xv 16 Preface xvi Stratus ftserver System Administrator s Guide for the Linux Operating System (R003L) 17 Chapter 1 Introduction to ftserver System Administration1- ftserver 2600, 4500, and 6300 systems running a supported Linux distribution together with ftserver System Software (ftsss) for the Linux Operating System operate as fault-tolerant servers. Every ftserver system uses replicated, fault-tolerant hardware to eliminate single points of failure and protect data integrity in all areas of data handling. The ActiveService Network (ASN) is an optional remote-monitoring system managed by Stratus. ASN architecture built into ftserver systems supports fault-tolerant features with self-checking hardware and onboard diagnostics to detect, isolate, and report potential problems before they affect server operation. NOTE Installation of ftsss and the Linux operating system is a bare-metal installation. You cannot install the fault-tolerant software in a guest operating system in a virtualized environment.For virtualization on ftserver systems, install VMware ESX TM and ftsss for VMware vsphere TM.

    For more information, see This introduction to ftserver system administration contains the following topics: Overview of System and Network Administration on page 1-2 Unsupported Linux Tools on page 1-4 System Documentation on page 1-4 Additional Documentation and Resources on page 1-5 Acronyms and Terms on page 1-5 Introduction to ftserver System Administration 1-1 18 Overview of System and Network Administration Overview of System and Network Administration This section presents an overview of the following commonly performed system administrative tasks: ftserver System Terminology Managing Data Storage Devices on page 1-2 Using Stratus Fault-Tolerant Tools and Software on page 1-3 Managing the System With SNMP on page 1-3 Managing Virtual Technician Modules (VTMs) on page 1-3 Troubleshooting ftserver Systems on page 1-4 To perform most of the documented procedures, you need root or superuser privileges. The procedures do not always specify when you need to have root privileges. NOTE The terms upper and lower refer to the location of the enclosures in a rack-mounted system. Managing Data Storage Devices In addition to disk storage, your system supports DVD drives, tape drives, and USB storage devices. Chapter 3, Managing Data Storage Devices, provides a discussion of these devices and the information needed to manage them. 1-2 Stratus ftserver System Administrator s Guide for the Linux Operating System (R003L) 19 Overview of System and Network Administration Using Stratus Fault-Tolerant Tools and Software While you can use standard Linux tools to perform many system administration tasks on your ftserver systems, some tasks on fault-tolerant systems require specialized supporting utilities. For additional information, see the Stratus ftserver System Software: Installation for Linux Systems (R013L). Managing the System With SNMP ftsss includes optional utilities to allow remote support of your ftserver system.

    These include an extensible network administration framework and a server-monitoring utility that provides notification services. Chapter 5, Simple Network Management Using Net-SNMP and ftlsnmp, discusses the configuration and use of the optional ftlsnmp package implementing Simple Network Management Protocol (SNMP) for managing network objects. The ftlsnmp package is typically installed with ftsss. Managing Virtual Technician Modules (VTMs) The Virtual Technician Module (VTM) console is a Web-based console that enables you, the CAC, or your authorized Stratus service representative to control, monitor, and diagnose the system. You can use the VTM console to control the host system even if the host system s operating system is unresponsive and its network connections are lost. Stratus ftserver System Software: Installation for Linux Systems (R013L) discusses how to configure VTMs for remote access. NOTE Starting with ftserver 2600, 4500, and 6300 systems, VTM functionality is integrated into the baseboard management controller (BMC). In previous ftserver Introduction to ftserver System Administration 1-3 20 Unsupported Linux Tools system models, the VTM and BMC were separate hardware components. Troubleshooting ftserver Systems Problem identification, system and application diagnostics, and system configuration to resolve problems with ftserver systems are essential troubleshooting tasks. Chapter 6 discusses system features and procedures to assist you in troubleshooting ftserver systems. Unsupported Linux Tools. CAUTION Avoid using the Linux sysreport command, a script that collects information about system execution. The sysreport command makes the system operate in simplex mode by taking a component offline for some time, eliminating fault-tolerant operation before bringing the component back online.!

    CAUTION Enabling and using the Sysrq tool causes system interruptions, because its use results in the suspension of kernel processes, which is interpreted by ftsss as a system hang. System Documentation The system documentation is available on the StrataDOC Web site and on a StrataDOC CD that was distributed with the system or ftsss upgrade. The documentation opens in a Web browser. 1-4 Stratus ftserver System Administrator s Guide for the Linux Operating System (R003L) 21 Additional Documentation and Resources Additional Documentation and Resources The following resources provide additional information that may be helpful to you in administering your ftserver system. Red Hat Enterprise Linux Documentation for the Red Hat Linux operating system is available at Stratus ftserver System Documentation The StrataDOC media provided with your system contains the ftserver system documentation for systems that run the Linux operating system. This documentation is provided in Adobe Acrobat Portable Document Format (PDF) and HTML format for viewing and printing. This manual occasionally refers to other documentation that is specific to your particular ftserver system. Table 1-1 lists the system-specific documentation, all of which is available on the ftserver StrataDOC media. Table 1-1. ftserver System-Specific Documentation Manual Stratus ftserver 2600, 4500, and 6300 Systems: Installation Guide (R640) Stratus ftserver 2600, 4500, and 6300 Systems: Operation and Maintenance Guide (R639) Description Describes how to install and set up your ftserver 2600, 4500, and 6300 system hardware. Documents how to operate, diagnose, and maintain your ftserver 2600, 4500, and 6300 system. It explains how to remove and replace the CRUs and how to interpret system operational status based on the state of the light-emitting diodes (LEDs). Acronyms and Terms Table 1-2 lists the acronyms and some terms used to describe tasks for administering ftserver systems. Table 1-2.

    Acronyms Used (Page 1 of 2) Acronym ASN BMC CAC Expanded Name ActiveService Network Baseboard management controller Customer Assistance Center Introduction to ftserver System Administration 1-5 22 Acronyms and Terms Table 1-2. Acronyms Used (Page 2 of 2) Acronym CRU DHCP DIMM Duplex DST EULA ftsmaint ftsss IPL MIB MTBF OSM SAS SATA Simplex SNMP UTC VFAT VTM Expanded Name Customer-replaceable unit Dynamic Host Configuration Protocol Dual-inline memory module The state of a device in an ftserver system in which the device has a running and healthy partner. In this case, the device can be removed without interrupting system operation. Daylight saving time End-user licensing agreement A command tool for managing your ftserver system s fault-tolerant functions.In this case, you cannot remove the device without disrupting the system operation. Simple Network Management Protocol Coordinated Universal Time Virtual file allocation table Virtual Technician Module 1-6 Stratus ftserver System Administrator s Guide for the Linux Operating System (R003L) 23 Chapter 2 Configuring the ftserver System2- This chapter discusses the following topics: Configuring Internal Disk Storage on page 2-2 Setting Up RAID Arrays on Internal Disks on page 2-9 Ethernet Devices on page 2-15 Other System Configuration Information on page 2-23 Additional Documentation and Resources on page 2-31 At system startup, the operating system probes hardware for legacy devices and attached devices that are not already configured for use on the system. Often, the device is recognized and automatically supported, requiring no direct configuration. While the operating system may recognize legacy devices, ftsss does not support them as fault-tolerant devices. To be supported as a fault-tolerant device, a device must have a special hardened driver that supports surprise removal and fault management by ftsss. Some system components, such as data storage, may require additional configuration.